IMJ00503 V3E.DOC Page 12 of 40 19.02.2009
Interface
Data interface Profibus RS485 . Ident. no. 0x09CB
Profibus DP V0 slave under IEC 61158 / IEC 61784 External
termination resistor
Baud rate 9.6 / 19.2 / 93.75 / 187.5 / 500 kbaud
1.5 / 3 / 6 / 12 Mbaud
Automatic baud rate detection
GSD file LMCJ40_3.GSD
PNO Profile Encoder Class 1/2. Configuration of measuring
parameters. Output of measured values and error messages
Parameters and PB address are stored in NVRAM
SSI interface Transfer rate: 50 kHz ... 1 MHz, 200 s break
Signal input to signal output differential signal (RS422), 24bit, gray
encoded, Slave. Electrical isolation to 500 V for signal input
Operation modes Continuous measurement external triggering
Switching output Two outputs with HIGH signal level VCC 2 V and LOW signal level
< 2 V; max. load carrying capacity 0.5 A, short circuit proof;
switching threshold and hysteresis selectable
Trigger input One input with HIGH signal level > 11 V and LOW signal level <
6.5 V. 2.5 mA input current at 24 V Trigger edge and delay
selectable Trigger pulse of max. 24 V
Environment
&
Ambient Conditions
Operating temperature 10 °C ... +50 °C with automatic laser diode shut down on
excession of temperature limits
Temperature
measurement
Internal
Storage temperature 20 °C ... +70 °C
Humidity < 65%
Dimensions (L x W x H) 210 mm x 96 mm x 50 mm
Weight 770 g
Protection type IP 66