4.2 Technical Data
Measuring Performance
Measuring principle Comparative phase measurement
Measuring parameter Distances
Measuring range
*1
0.1 m ... 30 m for natural, diffusely reflecting surfaces, and up to
150 m with a target board
Measuring accuracy ± 2 mm for white surfaces, (+15 °C ... +30 °C)
± 3 mm for natural surfaces, (+15 °C ... +30 °C)
Target surface Of natural, diffusely reflecting type
Target board required From 30 m to 150 m
Measured value
resolution
0.1 mm
Reproducibility
<+-
0.5 mm
Measuring time 0.16 sec ... 6 sec on white target board (10 Hz mode) 20 msec on
white target board (50 Hz mode)
Max. carrier motion
speed
4 m p. sec in “DX” operating mode
*1
conditional on target reflectance, ambient light influences and atmospheric conditions
Laser
Laserclass Laserclass2,≤1mWconformingtostandard
IEC 825 1 / EN 60829
Laser beam divergence 0.6 mrad
Wavelength 650 nm (red, visible)
Electric Power Requirements
Supply voltage 10 V ... 30 V DC
Max. power consumption 3.2 W at 24 V